Hotline:

15335271700

Model query X

NewsIndustry news

Location:Home > News > Rotary Bearing Operation and Maintenance Manual

Rotary Bearing Operation and Maintenance Manual

2025-09-18

Section 1: Installation Precautions

  1. Base Preparation

    • Ensure mounting surface flatness ≤0.02mm/m

    • Bolt pre-torque sequence follows manufacturer's cross-pattern specification

  2. Alignment Check

    • Use dial indicator to verify TIR (Total Indicator Reading) ≤0.05mm

Section 2: Daily Maintenance

Item

Frequency

Standard

Lubrication

500hrs

NLGI Grade 2 lithium grease

Bolt Inspection

Monthly

Torque variation ≤10%

Section 3: Troubleshooting

  • Abnormal Noise: Check gear meshing clearance (0.1-0.3mm)

  • Vibration: Verify raceway surface roughness Ra ≤1.6μm

Section 4: Extended Service Life Techniques

  1. Implement condition monitoring via vibration analysis

  2. Use synthetic grease for -30℃~150℃ applications